​LS SV037iG5A-4 VFD is a 3-phase AC motor controller with 3.7 kW/8.0 A capacity and wide 380–480 V input for pumps, fans, and conveyors. This model provides precise sensorless vector control with Built-in RS485 (Modbus RTU), detailing its troubleshooting and compatibility for any necessary replacement and upgrades.
Industrial Components: Tech Specs, Wiring/Installation, Troubleshooting, Replacement

상품 선택옵션 0 개, 추가옵션 0 개

Price US$1,000.00
Shipping Fee Paid at Checkout
Availability In stock

선택된 옵션

  • LS SV037iG5A-4
    +US$0.00
* Customs duties and VAT incurred during import clearance are the buyer's responsibility and are not included in the total amount.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: LS SV037iG5A-4 (iG5A, Variable Frequency Drive)

Role/Application: Compact three-phase AC motor controller with sensorless vector control for precise speed and torque management in pumps, fans, and conveyor systems.

KEY SPECS SUMMARY

Power: 3.7 kW / 8.0 A

Interfaces / Ports: Built-in RS485 (Modbus RTU)

Indicators: Four LEDs: SET, RUN, FWD, REV

Operating Temp: minus 10 to 50 degrees C

Platform / Compatibility: Sensorless Vector Control, PID control

Limit: Max 1000m altitude, 90 percent RH humidity

Lifecycle: Discontinued model

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What is the maximum output frequency of the SV037iG5A-4 VFD?

A: The maximum adjustable output frequency is 400 Hz.

Wiring & Installation:

Q: What is the recommended ground impedance for this 400V class inverter?

A: Recommended ground impedance is below 10 ohm.

Troubleshooting & Compatibility:

Q: What are the main fault trip conditions monitored by the iG5A series VFD?

A: Overvoltage, undervoltage, overcurrent, ground fault, and inverter overheat.

Replacement & Upgrades:

Q: Is the SV037iG5A-4 model still in active production by the manufacturer?

A: No, this model is discontinued. Refer to the latest manufacturer manual.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing