SICK PBS2-RB600SG1NSDNMA0Z is a high-precision pressure sensor (0 bar to 600 bar) with IO-Link, PNP/NPN, and analog (4 mA - 20 mA, 0 V - 10 V) outputs for automation system integration. It supports -20 C to +85 C operation and +/-3 percent zero point adjustment; locate technical specifications and wiring and installation guides for dependable high-pressure monitoring.
SICK: Product Insights  |  SICK: Technical Guides

상품 선택옵션 0 개, 추가옵션 0 개

Price US$691.67
Shipping Fee Paid at Checkout
Brand SICK
Model PBS2-RB600SG1NSDNMA0Z 6079249
Availability In stock

선택된 옵션

  • SICK PBS2-RB600SG1NSDNMA0Z 6079249
    +US$0.00
* Customs duties and VAT incurred during import clearance are the buyer's responsibility and are not included in the total amount.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: SICK PBS2-RB600SG1NSDNMA0Z (PBS plus, Pressure Sensor)

Role/Application: High-precision gauge pressure sensor with an integrated display, offering IO-Link communication and flexible digital/analog outputs for monitoring high pressure up to 600 bar in industrial automation.

KEY SPECS SUMMARY

Power: 15 V DC to 35 V DC

Interfaces / Ports: M12 x 1, 4-pin round connector

Indicators: 14-Segment LED, red, 4-digit

Operating Temp: Minus 20 to 80 degrees C (Ambient)

Platform / Compatibility: IO-Link V1.1

Limit: 0 bar to 600 bar measuring range

Lifecycle: Active

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What is the maximum measurement accuracy and typical power consumption of the sensor?

A: The max accuracy is less than or equal to plus/minus 0.5 percent of the span, with 70 mA typical consumption.

Wiring & Installation:

Q: What is the mechanical process connection type and the default seal material used?

A: The process connection is G one quarter A (ISO1179-2), with a standard NBR seal.

Troubleshooting & Compatibility:

Q: Can the analog output signal be set to either current or voltage simultaneously with the IO-Link?

A: Yes, it provides IO-Link/PNP/NPN plus a switchable analog output of 4 mA to 20 mA or 0 V to 10 V.

Replacement & Upgrades:

Q: What is the typical long-term stability or drift expected over one year of operation?

A: Long-term drift is less than or equal to plus/minus 0.1 percent of span per year.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing