GE Fanuc (EMERSON) IC695HSC308 High-Speed Counter Module enables fast, reliable, and high-resolution counting for precise signal processing and demanding motion control applications. It features 8 counters, 1.5 MHz max frequency, and a 32-bit counting range; refer to the technical specifications for detailed performance charts and consult the troubleshooting and compatibility guide for optimal setup in turbine flowmeter systems.
EMERSON: Product Insights  |  EMERSON: Technical Guides

상품 선택옵션 0 개, 추가옵션 0 개

Price US$3,083.33
Shipping Fee Paid at Checkout
Brand EMERSON
Model IC695HSC308
Availability In stock

선택된 옵션

  • EMERSON IC695HSC308
    +US$0.00
* Customs duties and VAT incurred during import clearance are the buyer's responsibility and are not included in the total amount.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: GE Fanuc IC695HSC308 (PACSystems RX3i, High-Speed Counter Module)

Role/Application: An 8-channel specialty module for the RX3i platform that processes rapid pulse signals up to 1.5 MHz for precise motion control, velocity measurement, and flowmeter applications.

KEY SPECS SUMMARY

Power: 94 mA max at 5 V, 561 mA max at 3.3 V

Interfaces / Ports: 16 inputs and 14 outputs

Indicators: Module status, field status, terminal block

Operating Temp: 0 degrees C to 60 degrees C

Platform / Compatibility: RX3i Universal Backplanes

Limit: 1.5 MHz max frequency; 1.5 A max per output channel

Lifecycle: Active

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What are the input and output counter points provided by the module?

A: The IC695HSC308 provides 16 high-speed inputs and 14 configurable high-speed outputs.

Wiring & Installation:

Q: What are the two nominal input voltage options supported by the counter inputs?

A: The inputs support 5 VDC nominal or 12 to 24 VDC nominal voltage ranges.

Troubleshooting & Compatibility:

Q: What maximum current and duration does the output short circuit protection tolerate?

A: The output will tolerate 4.5 A for a maximum of 450 µS before self-protection trips.

Replacement & Upgrades:

Q: What are the isolation ratings between the field and the controller backplane?

A: Isolation is 250 VAC continuous and 2500 VAC for one minute, field to backplane.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing