​Allen-Bradley 1746-OW8 Digital Contact Output Module provides stable output control for SLC 500 using eight Normally Open relay channels. It supports 5 to 265V AC or 5 to 125V DC operation across two output groups; examine all technical specifications before starting wiring and installation for correct setup.
Allen-Bradley: Product Insights  |  Allen-Bradley: Technical Guides

상품 선택옵션 0 개, 추가옵션 0 개

Price US$4,250.00
Shipping Fee Paid at Checkout
Brand Allen-Bradley
Model 1746-OW8
Availability In stock

선택된 옵션

  • Allen-Bradley 1746-OW8
    +US$0.00
* Customs duties and VAT incurred during import clearance are the buyer's responsibility and are not included in the total amount.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: Allen-Bradley 1746-OW8 (SLC 500, Digital Contact Output Module)

The 1746-OW8 is a relay output module for the SLC 500, featuring eight Normally Open channels organized into two isolated groups. It supports control of both AC (up to 265V) and DC (up to 125V) field devices.

KEY SPECS SUMMARY

Power: 5V DC, 120 mA (backplane)

Interfaces / Ports: One 20-pin connector

Indicators: Eight output status LEDs

Operating Temp: 0 to 60 degrees C

Platform / Compatibility: SLC 500 modular hardware

Limit: 8 relay outputs; 2 isolated groups

Lifecycle: Active replacement part

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What is the maximum current rating for a single relay output channel on the 1746-OW8?

A: The maximum output current per point is rated at 2.0 A resistive load.

Wiring & Installation:

Q: Why must the 1746-OW8 be wired using the two isolated output groups?

A: The isolation allows the module to control loads using two different voltage levels or power sources.

Troubleshooting & Compatibility:

Q: What does a flashing status LED on one of the output channels typically signify?

A: A flashing LED indicates a potential issue with the field wiring or an excessive load current on that channel.

Replacement & Upgrades:

Q: When upgrading from the 1746-OW8, what is the main consideration for relay outputs?

A: Modernizing often involves selecting a compatible ControlLogix or CompactLogix relay output module.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing