OMRON CJ1W-DA08V

Omron CJ1W-DA08V Analog Output Module features 8 voltage channels with 12-bit resolution, delivering precise control at 1 ms per point D/A conversion speed. This PLC unit supports 0 to 10 V output with plus minus 0.5 percent accuracy; consult the technical specifications to evaluate potential replacement options.
OMRON: Product Insights  |  OMRON: Technical Guides

상품 선택옵션 0 개, 추가옵션 0 개

가격 US$1,758.33
배송비 주문 시 결제
브랜드 OMRON
모델명 CJ1W-DA08V
상태 판매 중

선택된 옵션

  • OMRON CJ1W-DA08V
    +US$0.00
* 통관 과정에서 발생하는 관세 및 부가가치세는 구매자 부담이며, 총 결제금액에 포함되어 있지 않습니다.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: Omron CJ1W-DA08V (CJ1W Series, Analog Output Unit)

Role/Application: This Special I/O Unit provides eight channels of high-speed, 12-bit D/A conversion for voltage output, allowing the CJ-series PLC to precisely control analog peripherals.

KEY SPECS SUMMARY

Power: 5 VDC 140 mA max

Interfaces / Ports: Screw terminal

Indicators: Refer to the latest manufacturer manual.

Operating Temp: 0 to 55 degrees C

Platform / Compatibility: CJ/CS/NJ-series PLC

Limit: 75% relative humidity

Lifecycle: Active

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What are the primary analog voltage output ranges supported by the CJ1W-DA08V module?

A: Supported ranges include 0 to 10 V, 1 to 5 V, 0 to 5 V, and a bipolar range of minus 10 to plus 10 V.

Wiring & Installation:

Q: What is the rated accuracy of the voltage output at an ambient temperature of 25 degrees C?

A: The accuracy is plus minus 0.3 percent of the full scale value at 25 degrees C.

Troubleshooting & Compatibility:

Q: What is the conversion time per point for the D/A process on this module?

A: The conversion time is 1 millisecond per point for analog output signal generation.

Replacement & Upgrades:

Q: What is the resolution of the analog output and the corresponding digital input range?

A: Resolution is 12-bit (1/4000) corresponding to a digital input range of 0 to 4000 or minus 4000 to plus 4000.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing