Allen-Bradley 1790D-T16BV0 Bulletin 1790D universal input base block features 16 channels supporting both sinking and sourcing types at 24 VDC. With a 3 mA input current, IP20 protection, and a removable terminal block, this module ensures reliable signal management, find the technical specifications and wiring and installation guide.
Allen-Bradley: Product Insights  |  Allen-Bradley: Technical Guides

상품 선택옵션 0 개, 추가옵션 0 개

Price US$916.67
Shipping Fee Paid at Checkout
Brand Allen-Bradley
Model 1790D-T16BV0
Availability In stock

선택된 옵션

  • Allen-Bradley 1790D-T16BV0
    +US$0.00
* Customs duties and VAT incurred during import clearance are the buyer's responsibility and are not included in the total amount.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: Allen-Bradley 1790D-T16BV0 (CompactBlock LDX, Universal DC Input Base Block)

Role/Application: A CompactBlock LDX DeviceNet base module providing 16 universal digital inputs (sinking or sourcing) for 24V DC field devices, mounted inside an enclosure.

KEY SPECS SUMMARY

Power: 24V DC, 8 mA per channel max

Interfaces / Ports: Removable Screw Terminal Block

Indicators: Network and module status LEDs

Operating Temp: 0 degrees C to 60 degrees C

Platform / Compatibility: CompactBlock LDX, DeviceNet

Limit: Response time 2 milliseconds

Lifecycle: Refer to the latest manufacturer manual.

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What are the minimum and maximum on-state input voltages for the 1790D-T16BV0?

A: The minimum on-state voltage is 9.6V DC and the maximum is 28.8V DC.

Wiring & Installation:

Q: How is the sinking or sourcing configuration determined for the 1790D-T16BV0 inputs?

A: Sinking or sourcing is configured by the wiring connection to the common terminal.

Troubleshooting & Compatibility:

Q: What is the procedure for setting the DeviceNet node address on the base block?

A: The node address is set using the two rotary switches on the front of the block at power up.

Replacement & Upgrades:

Q: What are the primary mounting options available for the CompactBlock LDX base block units?

A: The modules are designed for secure mounting on a standard DIN rail or directly onto a panel.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing