Allen-Bradley 1762-IR4

Allen-Bradley 1762-IR4 is a MicroLogix RTD and resistance input module with four channels for precise temperature measurement in industrial automation systems. It supports diverse RTD types (100–1000 Ohm Platinum) and resistance inputs (0–3000 Ohm), serving as a reliable expansion for MicroLogix 1100/1200/1400 PLCs access crucial technical specifications and wiring and installation documentation.
Allen-Bradley: Product Insights  |  Allen-Bradley: Technical Guides

상품 선택옵션 0 개, 추가옵션 0 개

가격 US$1,541.67
배송비 주문 시 결제
브랜드 Allen-Bradley
모델명 1762-IR4
상태 판매 중

선택된 옵션

  • Allen-Bradley 1762-IR4
    +US$0.00
* 통관 과정에서 발생하는 관세 및 부가가치세는 구매자 부담이며, 총 결제금액에 포함되어 있지 않습니다.
위시리스트

상품 정보

상품 상세설명

OVERVIEW

Official designation: Allen-Bradley 1762-IR4 (MicroLogix Series, RTD/Resistance Input Module)

Role/Application: This 4-channel specialty expansion module acquires temperature data from RTDs or resistance values up to 3000 Ohm. It is compatible with MicroLogix 1100, 1200, and 1400 controllers for precise industrial temperature monitoring.

KEY SPECS SUMMARY

Power: 40 mA at 5V DC bus

Interfaces / Ports: Removable screw connection

Indicators: Power diagnostic LED

Operating Temp: 0 to 55 degrees C

Platform / Compatibility: MicroLogix 1100/1200/1400

Limit: Input to system isolation 707V DC

Lifecycle: Current Product

FREQUENTLY ASKED QUESTIONS

Technical Specifications:

Q: What are the input current excitation values provided for the RTD and resistance sensors?

A: The module provides either 0.5 mA or 1.0 mA excitation current to the connected sensors.

Wiring & Installation:

Q: What are the installation requirements regarding spacing for the 1762-IR4 module?

A: Maintain a minimum spacing of 50.8 mm (2 in.) on all sides for adequate ventilation.

Troubleshooting & Compatibility:

Q: What is the input-to-system isolation test voltage for the RTD/Resistance module?

A: The module is type tested for input group to system isolation at 707V DC for 1 minute.

Replacement & Upgrades:

Q: Is this MicroLogix RTD/Resistance module currently available for new installations?

A: Yes, the 1762-IR4 module is currently listed as an existing product in the MicroLogix line.

상품 정보 고시

Category Details
Product Name See this page for details
Model Name See this page for details
Certification or Licensing Information Required by Law See this page for details
Country of Manufacture or Origin See this page for details
Manufacturer See this page for details
After-sales Service Contact or Customer Support Number See this page for details

사용후기

등록된 사용후기

Be the first to leave a review!

상품문의

등록된 상품문의

Be the first to ask a question about this product!

배송정보

Service Information
 

교환/반품

Caution When Purchasing